Mine Safety Appliances
North America
Select Region
Corporate Home
Africa
Asia Pacific
Europe
Latin America
Middle East
MSA is the global leader in the development, manufacture and supply of sophisticated products that protect people's health and safety.
MSA Customer ServiceCustomer Service
1-800-MSA-2222

MSA Sales Manager LocatorSales Manager Locator

Instrument Repair ServicesInstrument Repair Services


The Safety Company



Related Resources
Response Respirator Selector

MSA Fire Service Website

Regulatory Information

Repair Education - CARE

Warranty Information

Ask a Question

Have Someone Call Me

Image Library

 
PremAire® Supplied Air Respirator System
HOME | CATALOG | SUPPLIED AIR RESPIRATORS | AIRLINE RESPIRATORS | PremAire® Supplied Air Respirator System

Printable Version of This Page
Email This Page

Enlarge Image





Principles of Operation
The PremAire Respirator is a full-face, pressure-demand, Type-C supplied-air respirator with a patented waist-mounted manifold that gives it incredible flexibility. Featuring five individual ports, the manifold makes it possible to add any of these capabilities:

Supplied-air respirator with emergency-escape air cylinder for egress from IDLH atmospheres.

Combination supplied-air/air-purifying respirator, which lets you move freely from station to station without being tethered to an air-supply hose, yet still be protected by the device's air-purifying capability.

Supplied-air respirator with dual-supply capability -- an MSA exclusive that eliminates the need to drag long lengths of air-supply hose around the work area.

Supplied-air respirator with Vortex tube, which provides body cooling, or warming, whenever protective clothing is required.

No matter which option you choose, you'll find that the PremAire System provides dependable protection, engineering excellence and cost-effective versatility.

Approvals & Standards
The PremAire Supplied-Air Respirator System has received National Institute for Occupational Safety and Health (NIOSH) certification for use in atmospheres not immediately dangerous to life or health (Non-IDLH)*. When equipped with the emergency-escape cylinder option and the Ultravue or Ultra Elite pressure-demand facepieces, the PremAire System is also approved for use in IDLH atmospheres.

WARNING: Duo-Twin Facepiece-equipped respirators are not approved for IDLH applications, even if equipped with the emergency-escape cylinder option.

Units are approved for use with an operating inlet pressure of 60-100 psig, and only when used with MSA Air-Supply Hose. See special use section of instructions for specific use limitations. The PremAire System requires a source of compressed air conforming to at least Quality Verification Level (Grade) D Compressed Gas Association, Inc., Commodity Specification for Air, G-7.1.

*Not immediately dangerous to life or health is defined in 42 CFR Part 84 as any hazardous atmosphere which may produce physical discomfort immediately, chronic poisoning after repeated exposure, or acute adverse physiological symptoms after prolonged exposure.

Applications
Asbestos Abatement
Chemical
Construction
Electric Utility
Hazardous Materials
Nuclear
Oil and Gas
Paper & Pulp
Sanding & Grinding
Spray Painting
Welding

Hazards
Confined Space
Oxygen Deficiency
Toxic Atmosphere IDLH
Toxic Atmosphere Non-IDLH

Product Information
The basic PremAire respirator includes a patented manifold and choice of four upgrade options. An escape cylinder option permits emergency escape from Immediately Dangerous to Life and Health (IDLH) atmospheres. A Dual-Supply option lets workers connect from one pressurized continuous air source to another without losing continuity of air flow. A Duo-Twin option converts the respirator into a combination supplied air/air-purifying device. This allows workers in non-IDLH atmospheres to move freely from station to station without being tethered to an air-supply hose. A vortex tube option delivers whole-body temperature control for added worker comfort.

Basic Info
Additional Product Information
  • NIOSH Approval Label - Premaire Duo-Twin (Matrix 818364)
  • NIOSH Approval Label - PremAire with Cylinder (Matrix 816921)
  • Bulletin - A Pocket Guide to Air-Line Systems (Bulletin No. 0114-14-MC)
  • Bulletin - Key Elements of a Sound Respiratory Protection Program (Bulletin No. 1000-61)
  • Bulletin - The PremAire Supplied Air Respirator System (Bulletin No. 0114-20-MC)
  • NIOSH Approval Label - PremAire & PremAire Cadet (Matrix 816843)
  • NIOSH Approval Label - PremAire Respirator with Firehawk (Matrix 10032761)


Technical Information
  • Suit Air Distribution System Instructions for Manifold Assembly (Manual Part No. 806095)
  • Instruction Manual for PremAire Vortex Tube Mode of Operation P/N 497231
  • Parts List - PremAire Supplied Air Respirator System (Manual Part No. 800000)
  • Instruction Manual for PremAire Duo-Twin Mode of Operation P/N 818370 (supplemental to manual P/N 496958)
  • PremAire System Instruction Manual (P/N 496958)
  • Instruction Manual for PremAire Dual-Supply Mode of Operation P/N 497230
  • Instruction Manual - Premaire Users Maintenance Instruction Manual (Manual Part No. 10017251)
  • Instruction Manual for PremAire Cylinder Mode of Operation P/N 800808


Literature
How to Order From MSA:
  • General Instructions
  • Locate an MSA Distributor
  • Locate an MSA Sales Manager


  • Frequently Ordered Part Numbers:

    496823 RESPIRATOR ASSY,PREMAIRE,UV,W/O CASE
    496896 RESPIRATOR ASSY,PREMAIRE,5-MIN CYL,W/CS
    496958 MANUAL,MMR,HIP AIR
    497230 MANUAL,INSTRUCTION,DUAL
    497231 MANUAL,INST,SUITABLE-AIRE
    497291 RESPIRATOR ASSY,PREMAIRE,W/10-MIN CYL&CS
    800000 PARTS LIST,PREMAIRE SYSTM
    800808 MANUAL,INSTR.,KIT,MMR
    800809 MANUAL,INSTR.,DUO-TWIN
    802996 GUIDE,USER,PREM-AIRE SYS.
    802997 BINDER,3 RING,PREM-AIRE
    802998 TABS,SET OF SIX,PREM-AIRE
    802999 CHART,QUICK REF.PREM-AIRE
    C-PS PREMAIRE A-T-O MATRIX
Ordering Info